10 PPLANNINGLANNING——EEXHAUSTXHAUST SSYSTEMSYSTEMS PELLET VENT MUST MAINTAIN A MINIMUM 3” CLEARANCE TO ANY COMBUSTIBLE (INSTALL VENT AT CLEARANCES
11 PPLANNINGLANNING—— EEXHAUSTXHAUST SSYSTEMSYSTEMS … … CONTINUEDCONTINUED DETERMINE VENTING SIZE AND DISTANCE: It is recommended that the ven
12 PPLANNINGLANNING—— EEXHAUSTXHAUST SSYSTEMSYSTEMS … … CONTINUEDCONTINUED PELLET VENT TERMINATION: (Figures 7 & 8) Termination must be a min
13 PPLANNINGLANNING—— OOUTSIDEUTSIDE AAIRIR Outside air is REQUIRED ON ALL MOBILE HOME INSTALLATIONS. Outside air is strongly recommended for all
14 PPLANNINGLANNING—— PPROTECTIONROTECTION & C& CLEARANCESLEARANCES STOVE PLACEMENT: FLOOR PROTECTION REQUIREMENTS: MINIMUM CLEARANCES T
15 16”PPLANNINGLANNING—— PPROTECTIONROTECTION & C& CLEARANCESLEARANCES . . . C. . . CONON’’TT CLEARANCES – “CORNER INSTALLATION”:
16 TTOOLSOOLS RREQUIREDEQUIRED Power Tools Shop Vacuum WITH Filter Jigsaw or Reciprocating saw Electric drill Extension cord 4” or 5” di
17 IINSTALLATIONNSTALLATION——FFREESTANDINGREESTANDING THROUGH THE WALL, DIRECT VENT INSTALLATION. (not preferred) (Figure 18) 1.
18 MMOBILEOBILE HHOMEOME IINSTALLATIONNSTALLATION CAUTION: DO NOT INSTALL STOVE IN SLEEPING ROOM THE STRUCTURAL INTEGRITY OF THE MANUFACTURED H
19 Walkout Basement or Main FloorBasement or Main Floor1Pipe AdapterClean Out Tee & CapTee Support BracketHorizontal Rain Cap234567890 Deg Elbow3
2 Glow Boy Pellet & Biomass www.glowboystoves.com 2 Friendly Reminder: A pellet stove / insert is not design
20 FFIREPLACEIREPLACE IINSERTNSERT IINSTALLATIONNSTALLATION 2Main Floor - Tie-In Claytile Flue1“PL” Pipe AdapterSingle Wall Stainless SteelCl
21 Installing Pellet Inserts into Factory Built or Masonry Fireplaces . . . cont Means must be provided for removal of the insert to clean the c
22 CAUTION: DO NOT BLOCK ANY VENT OPENINGS PELLET VENT MUST MAINTAIN A MINIMUM 3” CLEARANCE TO ANY COMBUSTIBLE. (INSTALL VENT AT CLEARANCES S
23 Glow Boy Pellet & Biomass www.glowboystoves.com 23 8”6”Wall Band / Support Brktevery 5’Wood FrameCons
24 OOPERATINGPERATING IINSTRUCTIONSNSTRUCTIONS COMPLETE THE CHECK LIST (Page 9) PRIOR TO LIGHTING YOUR FIRST FIRE FOLLOW THE ARROWS TO START YOUR
25 OOPERATINGPERATING IINSTRUCTIONSNSTRUCTIONS FILL THE HOPPER WITH FUEL: Open the hopper lid by placing your fingers in the recessed handle on t
26 OOPERATINGPERATING IINSTRUCTIONSNSTRUCTIONS IMPORTANT: If at anytime your appliance does not seem to be operating as it had,
27 OPERATING IN THERMOSTAT HIGH / LOW CYCLE (Flashing 3 & 4) This requires purchasing the optional “Wall Thermostat Add-on Kit”. This mode o
28 OOPERATINGPERATING IINSTRUCTIONSNSTRUCTIONS OPERATING IN THERMOSTAT ON / OFF (Flashing 1 & 2) This also requires purchasing the option
29 OOPERATINGPERATING IINSTRUCTIONNSTRUCTION—— LLIGHTINGIGHTING YYOUROUR AAPPLIANCEPPLIANCE Before lighting a fire check to ensure the Burn Grate
3 TTABLEABLE OFOF CCONTENTSONTENTS GENERAL INFORMATION MAINTENANCE SAFETY PRECAUTIONS 4 REQUIRED ROUTINE CLEANING 33 SAFETY TE
30 OOPERATIONPERATION—— PPERFORMANCEERFORMANCE EENHANCEMENTSNHANCEMENTS A HIGH QUALITY FIRE should burn with a brisk, vibrant, yellow to white col
31 FFUELUEL SSPECIFICATIONSPECIFICATIONS——WWOODOOD PPELLETSELLETS The performance of your pellet appliance is greatly affected by the type and q
32 FFUELUEL SSPECIFICATIONSPECIFICATIONS——SSHELLEDHELLED CCORNORN The performance of your multi-fuel burning appliance is greatly affected by the
33 MMAINTENANCEAINTENANCE——RROUTINEOUTINE CCLEANINGLEANING Proper care of your Glow Boy SERIES pellet appliance is required for peak, sustained
34 MMAINTENANCEAINTENANCE—— PPERIODICERIODIC CCLEANINGLEANING 1 TON, SEASONAL OR BI-SEASONAL The #1 reason for a service call or unit failing
35 FAN MOTORS: Clean the in-take on CONVECTION (ROOM AIR) fan as well as the air holes on the motors of both COMBUSTION and CONVECTION fans annually
36 TTROUBLEROUBLE SSHOOTINGHOOTING Proper cleaning, maintenance and the use of clean, dry, quality fuel will prevent the more common stove oper
37 TTROUBLEROUBLE SSHOOTINGHOOTING PROBLEM CAUSE SOLUTION Stove Will Not Start (cont….) 4. Air Inlet Damper setting *Check for proper setti
38 TTROUBLEROUBLE SSHOOTINGHOOTING PROBLEM CAUSE SOLUTION Fire burns with a yellow flame. Fuel builds up in the burn grate. Window gets real
39 OOPTIONALPTIONAL AACCESSORIESCCESSORIES OPTIONAL ITEMS SEE YOUR “Glow Boy” DEALER FOR ADDITIONAL INFORMATION OR TO ORDER. Part No. Descripti
4 SSAFETYAFETY PPRECAUTIONSRECAUTIONS • BEFORE installing or having the pellet appliance installed contact the local building officials to obtain t
40 LLIMITEDIMITED WWARRANTYARRANTY Additional Dansons Products www.louisiana-grills.com www.countrysmokers.com Check our website for up to
5 • DO NOT operate the stove if the flame becomes dark and sooty or if the firepot overfills with pellets. Push the OFF Touch Pad and inspect the h
6 HHOWOW YYOUROUR AAPPLIANCEPPLIANCE WWORKSORKS Cautions: Do not try to operate your stove with viewing door open. Pellets will not feed under t
7 AAUTOMATICUTOMATIC SSAFETYAFETY FFEATURESEATURES L120 LOW LIMIT SWITCH This limit switch is mounted on the exhaust blower housing and has 2 main
8 SSPECIFICATIONSPECIFICATIONS HEATING SPECIFICATIONS DIMENSIONS Product subject to Change without notice. ELECTRICAL SPECIFICATIONS
9 PPLANNINGLANNING & I& INSTALLATIONNSTALLATION CCHECKHECK LLISTIST Unless you are knowledgeable and experienced in stove installation, we